Access Point Technologies EP offers a full line of EP diagnostic and Ablation Catheters. APT EP Map-iT® Diagnostic Mapping Catheters can be used in the evaluation of a variety of cardiac arrhythmias from endocardial and intravascular sites.

FEATURED PRODUCTS

Guide-Tip™ 3.3/4F

(Small French) Catheters

HIS – RV™ Catheters

CS Reach™ – Steerable Catheters

CTI-Cath™ 6F & 7F

Duo-Deca

– 20 pole steerable Catheters

Steerable PV Catheters

Map-iT Extension Cables

APT EP Map-iT Catheters are designed to provide pacing and recording during invasive electrophysiology procedures.

Features of the APT EP Map-iT catheters:

  • Proprietary catheter shaft specific to APT EP Map-iT catheters that allows for superb torque control and pushability
  • Pt-ir electrodes for high quality signals
  • Variable electrode spacing for optimum pacing and recording
  • Smooth shaft-electrode interface for better recording quality
  • Ergonomic Handles
  • Large variety of catheter configuration to better accommodate physician preferences

Catalog / Info

Guide-Tip™ 3.3/4F Coronary Sinus (CS) Catheter

Guide-Tip - 3.3/4F coronary sinus (CS) catheter with guidewire tip allows for placement in smaller anatomies

Images Courtesy of Alan Bulava, MD, PhD, Ceske Budejovice Hospital, Czech Republic

Guide-Tip - 3.3/4F Guidewire Tip Catheter

White Paper link

Advantages of the 3.3/4F Catheters with Guidewire Tip

 

  • The physician will be able to cannulate the CS and it’s side branches
  • It can potentially be useful for deeper CS pacing to confirm the isolation of the PVs
  • Using this catheter, physicians can potentially go so deep into the CS it will be ideal for left-sided WPW cases to more precisely locate the site of the accessory pathway.
  • For posterior septal accessory pathways, doctors sometimes map within the middle cardiac vein (MCV) and this would potentially be ideal for doing that.
  • With its small profile, the CS Catheter is an option for use in patients with small or restrictive anatomy.  The physician may be able to;
  • cannulate the CS and side branches
  • confirm isolation of PVs
  • locate the site of accessory pathways

Guide-Tip - 3.3/4F Guidewire Tip Catheter

– 3.3/4F

– Decapolar and Duodecapolar

– Tip Configuration – Guidewire or 1.6mm electrode

– Curve – S

– Length – 75cm and 120cm

– Spacing – 5mm , 2-5-2mm, 2-8-2mm and 2-10-2mm

3F Fixed Deca and Duo-deca with Guidewire Tip Catheters

Loading...

HIS-RV™ Catheters

HIS-RV Catheters

  • Simultaneously record and/or pace HIS and RV sites with a single catheter

HIS-RV Catheters

  • 5F and 6F
  • Decapolar
  • Curve - MPA
  • Length - 120cm
  • Spacing - various options, see chart below

HIS-RV Catheters

Loading...

CS Reach™ Catheters

CS Reach Catheters

  • Designed to facilitate inferior access to the CS
  • Unique 3D curve helps negotiate difficult CS ostial anatomies

CS Reach Catheters

  • 4F, 5F, 6F and 7F
  • Quadripolar, Pentipolar and Decapolar
  • Curve – MPD-SL
  • Length – 110cm
  • Spacing – 5mm, 2-5-2mm, 2-8-2mm, 2-10-2mm, 2-2-2-175mm, 2-5-2-175mm and 5-5-5-175mm

CS Reach Catheters

Loading...

CTI-Cath - Duo-decapolar Catheters

  • MPD-L offset curve has a loop that opens to provide tissue contact and electrogram stability

CTI-Cath™ 6F & 7F Duo-decapolar Catheters

CTI-Cath

- Duo-decapolar Catheters

  • 6F and 7F
  • 20 electrodes
  • MPD-H: 5mm, 2-5-2mm, 2-8-2mm, 2-10-2mm and 2-8-2-..-60-..-2-8-2mm; MPD-L: 2-8-2mm only
  • Curves – MPD-H and MPD-L;
  • Length – 100cm
  • Requires two, 210cm decapolar cables (901957)

Steerable Duo-decapolar Catheters

Loading...

Steerable Curve PV Mapping Catheters

Steerable Curve PV Mapping Catheters

  • Full 180° deflection allows for access to the RIPV
  • PV catheter keeps its shape and deflection throughout the entire procedure  

Deflection compared to other available PV catheters

Maximum deflection of the competing PV catheter (left)

Maximum deflection of the Map-iT PV catheter (right)

Mapping Catheters

PV Mapping Catheters

  • 7F shaft 3F loop
  • 10 and 20 electrodes
  • Curves

Decapolar

  • MPD-PV12: 3mm
  • MPD-PV15: 4mm
  • MPD-PV18: 5mm
  • MPD-PV21: 6mm
  • MPD-PV24: 7mm

Duo-decapolar

  • MPD-PV12: 1-1-1mm
  • MPD-PV15: 1-2-1mm
  • MPD-PV18: 1-3-1mm
  • MPD-PV21: 1-4-1mm
  • MPD-PV24: 1-5-1mm
  • Length – 110cm
  • Cables: Uses the 150cm 901956 cable for the decapolar version and 901957 (needs two) for the Duo-decapolar version

Decapolar and Duo-decapolar PV Catheters

Loading...

Map-iT Extension Cables

Map-iT Extension Cables

Map-iT Extension cables are designed to connect the catheters to the appropriate electrode interface in the electrophysiology lab.

 

Key features

  • Guided channel for a fast convenient connection
  • Push button release
  • Terminal pins labeled with white characters

Catalog / Info

INTENDED USE/INDICATION FOR USE:

 

The APT EP Map-iT® Diagnostic Mapping Catheters can be used in the evaluation of a variety of cardiac arrhythmias from endocardial and intravascular sites.

See instructions for use for a complete list of warnings, precautions and contraindications.

APT EP Inc.

12560 Fletcher Lane

Suite 300

Rogers, MN 55374

Phone: 763-432-9004

Fax: 763-432-9305

www.AcesssPointUS.com

APT-EP ©2018

All Rights Reserved • Release Version 2018.1

Access Point Technologies EP offers a full line of EP diagnostic and Ablation Catheters. APT Map-It TM Diagnostic Mapping Catheters can be used in the evaluation of a variety of cardiac arrhythmias from endocardial and intravascular sites.

APT EP Map-iT™ Catheters are designed to provide pacing and recording during invasive electrophysiology procedures.

Features of the Map-iT™ catheters:

  • Proprietary catheter shaft specific to Map-iT™ catheters that allows for superb torque control and pushability
  • Pt-ir electrodes for high quality signals
  • Variable electrode spacing for optimum pacing and recording
  • Smooth shaft-electrode interface for better recording quality
  • Ergonomic Handles
  • Large variety of catheter configuration to better accommodate physician preferences